| Available in | Reverse Cycle – 7.1kW, 8.5kW, 10.0kW, 11.5kW, 13.0kW |
| Refrigerant | R410A |
quotes@abaircon.com.au
810 Princes Highway, Tempe NSW 2044
Tel: (02) 9559 5116
Slimline Plus Range
Out of stockOut of stock



| Sizes | 7.10kW(C) 8.00kW(H), 8.50kW(C) 10.00kW(H), 10.00kW(C) 11.20kW(H), 11.50kW(C) 14.00kW(H), 13.00kW(C) 16.00kW(H) |
|---|
Technical Specifications
| Attribute | ARTG24LHTDP7.10kW(C) 8.00kW(H)View model | ARTG30LHTDP8.50kW(C) 10.00kW(H)View model | ARTG36LHTDP10.00kW(C) 11.20kW(H)View model | ARTG45LHTDP11.50kW(C) 14.00kW(H)View model | ARTG54LHTDP13.00kW(C) 16.00kW(H)View model |
|---|
|
|
|
|
|
|
|
|---|---|---|---|---|---|
|
Operation Type
|
Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
|
Power SourceV/Ph/Hz
|
230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
|
Cooling CapacitykW (Rated (Min – Max))
|
7.10 (2.9 – 8.0) | 8.50 (2.8 – 10.0) | 10.00 (3.8 – 11.2) | 11.50 (4.0 – 13.3) | 13.00 (6.2 – 15.2) |
|
Heating CapacitykW (Rated (Min – Max))
|
8.00 (2.2 – 9.1) | 10.00 (2.7 – 11.2) | 11.20 (4.0 – 14.0) | 14.00 (4.2 – 15.5) | 16.00 (6.2 – 18.0) |
|
Input Power CoolingkW (Rated (Max))
|
2.08 (4.06) | 2.65 (4.06) | 3.11 (4.78) | 3.33 (5.00) | 3.92 (5.58) |
|
Input Power HeatingkW (Rated (Max))
|
2.19 (4.40) | 2.7 (4.06) | 3.07 (4.76) | 3.68 (5.02) | 4.45 (5.59) |
|
EER CoolingkW/kW
|
3.41 | 3.21 | 3.22 | 3.45 | 3.32 |
|
COP HeatingkW/kW
|
3.65 | 3.70 | 3.65 | 3.80 | 3.60 |
|
Star Rating Cooling(0-10) (Hot / Average / Cold)
|
3.0 / 2.5 / 3.0 | 2.5 / 2.0 / 2.5 | 2.5 / 2.5 / 2.5 | 3.0 / 2.5 / 3.0 | 3.0 / 2.5 / 2.5 |
|
Star Rating Heating(0-10) (Hot / Average / Cold)
|
2.5 / 2.0 / 1.5 | 2.5 / 2.0 / 1.5 | 2.5 / 2.0 / 1.5 | 2.5 / 2.0 / 1.5 | 2.5 / 2.0 / 1.5 |
|
Total Cooling Seasonal Performance Factor ResidentialkW (Hot / Average / Cold)
|
4.790 / 4.475 / 4.673 | 4.142 / 3.899 / 4.024 | 4.45 / 4.197 / 4.388 | 4.635 / 4.367 / 4.539 | 4.535 / 4.287 / 4.476 |
|
Heating Seasonal Performance Factor ResidentialkW (Hot / Average / Cold)
|
4.448 / 3.679 / 3.022 | 4.335 / 3.921 / 3.469 | 4.429 / 3.765 / 3.161 | 4.379 / 3.898 / 3.354 | 4.224 / 3.644 / 3.092 |
|
Total Cooling Seasonal Performance Factor CommercialkW (Hot / Average / Cold)
|
5.145 / 5.274 / 5.657 | 4.404 / 4.46 / 4.743 | 4.762 / 4.884 / 5.236 | 4.946 / 5.044 / 5.387 | 4.845 / 4.962 / 5.313 |
|
Heating Seasonal Performance Factor CommercialkW (Hot / Average / Cold)
|
4.452 / 3.826 / 3.320 | 4.334 / 4.082 / 3.699 | 4.433 / 4.045 / 3.409 | 4.376 / 4.072 / 3.636 | 4.224 / 3.741 / 3.307 |
|
Running Currentamps (Cooling / Heating)
|
8.7 / 9.2 | 11.1 / 11.3 | 13.0 / 12.9 | 14.0 / 15.4 | 16.5 / 18.7 |
|
Moisture Removall/hr
|
2.2 | 2.3 | 2.4 | 2.6 | 3.7 |
|
Indoor Sound Pressure CoolingdBA (High / Quiet)
|
33 / 21 | 37 / 29 | 36 / 26 | 40 / 29 | 40 / 29 |
|
Indoor Sound Pressure HeatingdBA (High / Quiet)
|
33 / 21 | 37 / 29 | 33 / 26 | 40 / 29 | 40 / 29 |
|
Outdoor Sound PressuredBA (Cooling / Heating)
|
55 / 56 | 53 / 55 | 54 / 55 | 55 / 55 | 55 / 57 |
|
Outdoor Sound PowerdBA
|
69 | 69 | 70 | 69 | 70 |
|
Static Pressure RangePA (Min to Max)
|
30 to 200 | 30 to 200 | 30 to 200 | 30 to 200 | 30 to 200 |
|
Air Circulation (Indoor – High Fan) Coolingl/sec
|
378 | 472 | 569 | 708 | 708 |
|
Air Circulation (Indoor – High Fan) Heatingl/sec
|
378 | 478 | 514 | 708 | 708 |
|
Indoor Unit Dimensionsmm (Height x Width x Depth)
|
300 x 1000 x 700 | 300 x 1000 x 700 | 300 x 1400 x 700 | 300 x 1400 x 700 | 300 x 1400 x 700 |
|
Indoor Unit Weightkg
|
36.00 | 36.00 | 46.00 | 46.00 | 46.00 |
|
Outdoor Unit Dimensionsmm (Height x Width x Depth)
|
620 x 790 x 290 | 830 x 900 x 330 | 830 x 900 x 330 | 1290 x 900 x 330 | 1290 x 900 x 330 |
|
Outdoor Unit Weightkg
|
41.00 | 61.00 | 61.00 | 86.00 | 93.00 |
|
Piping Connectsmm Ø (Liquid / Gas)
|
6.35 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
|
Pipe Lengthm (Max (Precharged))
|
30 (15) | 50 (20) | 50 (20) | 50 (20) | 75 (30) |
|
Max Height Differencem
|
20 | 30 | 30 | 30 | 30 |
|
Operation Range Cooling°CDB (Min to Max)
|
-10 to 46 | -15 to 46 | -15 to 46 | -15 to 46 | -15 to 46 |
|
Operation Range Heating°CDB (Min to Max)
|
-15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
|
Refrigerant Type
|
R410A | R410A | R410A | R410A | R410A |
|
Refrigerant Amountg
|
1,800 | 2,100 | 2,100 | 3,350 | 3,450 |
| Attribute |
|---|
|
Operation Type
|
|---|
|
Power SourceV/Ph/Hz
|
|
Cooling CapacitykW (Rated (Min – Max))
|
|
Heating CapacitykW (Rated (Min – Max))
|
|
Input Power CoolingkW (Rated (Max))
|
|
Input Power HeatingkW (Rated (Max))
|
|
EER CoolingkW/kW
|
|
COP HeatingkW/kW
|
|
Star Rating Cooling(0-10) (Hot / Average / Cold)
|
|
Star Rating Heating(0-10) (Hot / Average / Cold)
|
|
Total Cooling Seasonal Performance Factor ResidentialkW (Hot / Average / Cold)
|
|
Heating Seasonal Performance Factor ResidentialkW (Hot / Average / Cold)
|
|
Total Cooling Seasonal Performance Factor CommercialkW (Hot / Average / Cold)
|
|
Heating Seasonal Performance Factor CommercialkW (Hot / Average / Cold)
|
|
Running Currentamps (Cooling / Heating)
|
|
Moisture Removall/hr
|
|
Indoor Sound Pressure CoolingdBA (High / Quiet)
|
|
Indoor Sound Pressure HeatingdBA (High / Quiet)
|
|
Outdoor Sound PressuredBA (Cooling / Heating)
|
|
Outdoor Sound PowerdBA
|
|
Static Pressure RangePA (Min to Max)
|
|
Air Circulation (Indoor – High Fan) Coolingl/sec
|
|
Air Circulation (Indoor – High Fan) Heatingl/sec
|
|
Indoor Unit Dimensionsmm (Height x Width x Depth)
|
|
Indoor Unit Weightkg
|
|
Outdoor Unit Dimensionsmm (Height x Width x Depth)
|
|
Outdoor Unit Weightkg
|
|
Piping Connectsmm Ø (Liquid / Gas)
|
|
Pipe Lengthm (Max (Precharged))
|
|
Max Height Differencem
|
|
Operation Range Cooling°CDB (Min to Max)
|
|
Operation Range Heating°CDB (Min to Max)
|
|
Refrigerant Type
|
|
Refrigerant Amountg
|
All product information is provided as a guide only. Always check the manufacturer’s official site for updated specifications and details. https://www.fujitsugeneral.com.au/commercial-products/light-commercial/slimline-plus
Related Products
Ø 8″ / 200mm x 6m Insulated Flexible Ducting – R0.6 Thermal & Fire Rated
$33.00 inc GST ($30.00 ex GST)
Ø 16″ / 400mm x 6m Insulated Flexible Ducting – R0.6 Thermal & Fire Rated
$55.00 inc GST ($50.00 ex GST)
Ø 18″ / 450mm x 6m Insulated Flexible Ducting – R0.6 Thermal & Fire Rated
$75.00 inc GST ($68.18 ex GST)
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
Mitsubishi Heavy Industries (MHI) ducted system – FDU
$2,920.00 – $4,315.00Price range: $2,920.00 through $4,315.00
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
Mitsubishi Heavy Industries (MHI) – FDUM Series
$2,355.00 – $2,550.00Price range: $2,355.00 through $2,550.00
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
Mitsubishi Heavy Industries (MHI) – FDUA Series
$2,800.00 – $3,710.00Price range: $2,800.00 through $3,710.00
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page