Available in Reverse Cycle (Heating & Cooling)
-
Capacities 7.1kW, 8.5kW, 10.0kW, 12.5kW, 14.0kW, 16.0kW, 18.0kW, 20.0kW, 24.0kW
-
Refrigerant 7.1-16.0kW: R32 / 18.0-24.0kW: R410A
quotes@abaircon.com.au
810 Princes Highway, Tempe NSW 2044
Tel: (02) 9559 5116
Daikin ducted system – Premium Inverter




Daikin ducted system – Premium Inverter
$3,700.00 – $8,700.00Price range: $3,700.00 through $8,700.00
Engineered to deliver remarkable energy performance, design flexibility and R22 retrofit capability, the Premium Inverter series is the ultimate ducted solution.
| Weight | 200 kg |
|---|---|
| Dimensions | 120 × 120 × 120 cm |
| Sizes | 7.1KW, 8.5KW, 10KW, 12.5KW, 14KW, 16KW, 18kw, 20kw, 24kw, 18kw heating focus, 20kw heating focus, 24kw heating focus |
| Power | Single phase, Three phase |
Technical Specifications
Single Phase
| Indoor Unit | FDYA71AV19 | FDYA85AV19 | FDYA100AV19 | FDYA125AV19 | FDYA140AV19 | FDYA160AV19 | |
| Outdoor Unit | RZAS71C2V1 | RZAS85C2V1 | RZAS100C2V1 | RZAS125C2V1 | RZAS140C2V1 | RZAS160C2V1 | |
| Rated Capacity | Cool (kW) | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 16.0 |
| Heat (kW) | 7.5 | 10.0 | 12.5 | 15.0 | 16.5 | 18.0 | |
| Capacity Range | Cool (kW) | 3.2-8.0 | 3.7-10.0 | 5.0-11.2 | 5.0-14.0 | 5.0-16.0 | 7.3-17.0 |
| Heat (kW) | 2.2-9.0 | 3.0-11.2 | 5.1-14.0 | 4.1-16.0 | 6.7-18.0 | 7.0-20.0 | |
| Power Input (Rated) | Cool (kW) | 1.90 | 2.35 | 2.61 | 3.45 | 3.93 | 4.85 |
| Heat (kW) | 1.75 | 2.46 | 3.13 | 3.80 | 4.28 | 4.65 | |
| E.E.R/C.O.P | C/H | 3.74/4.29 | 3.62/4.07 | 3.83/3.99 | 3.62/3.95 | 3.56/3.86 | 3.30/3.87 |
| TCSPF (Residential) | Hot/Average/Cold | 5.20/4.50/4.55 | 4.99/4.40/4.45 | 4.69/4.22/4.25 | 4.96/4.47/4.59 | 5.00/4.54/4.67 | 4.77/4.37/4.55 |
| HSPF (Residential) | Hot/Average/Cold | 4.79/4.34/3.86 | 4.43/4.04/3.60 | 4.43/4.07/3.62 | 4.72/4.08/3.45 | 5.01/4.12/3.41 | 4.55/3.97/3.41 |
| Airflow Rate (Nominal/Max) | l/s | 425/566 | 580/600 | 680/800 | 755/840 | 900/1000 | 950/1120 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 37.3/40.5 | 42.0/42.5 | 42.3/45.0 | 44.8/46.2 | 45.9/47.4 | 47.2/49.6 |
| Piping Length | m | 75 | |||||
| Indoor Fan Speeds | H/M/L | ||||||
| Dimensions (HxWxD) | Indoor (mm) | 300x1210x900 | 360x1520x935 | 400x1505x980 | |||
| Outdoor (mm) | 990x940x320 | 1430x940x320 | |||||
| Weight | Indoor (kg) | 40 | 41 | 46 | 56 | 60 | 60 |
| Outdoor (kg) | 69 | 78 | 93 | 93 | 93 | 99 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz | |||||
| Compressor Type | Hermetically Sealed Swing Type | ||||||
| Refrigerant | R32 | ||||||
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) | |||||
| Gas (mm) | 15.9 (Flared) | ||||||
| Drain (mm) | ID 25 / OD 32 | ||||||
| Supply Air Opening | mm (HxW, Flange) | 185×852 | 245×1152 | 295×1152 | |||
| Return Air Opening | mm | 1×400 (Oval) | 2×350 (Oval) | 2×400 (Oval) | |||
| Outdoor Operating Range | Cool (°CDB) | -5 to 50 | |||||
| Heat (°CWB) | -15 to 16 | ||||||
| EPA Sound Power Level | dBA | 67 | 71 | 70 | 71 | 73 | 75 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 48/50 | 52/53 | 51/53 | 52/54 | 54/56 | 56/58 |
Three Phase
| Indoor Unit | FDYQ180LCV1 | FDYQ200LCV1 | FDYQ250LCV1 | FDYQ180LCV1 | FDYQ200LCV1 | FDYQ250LCV1 | |
| Outdoor Unit | RZYQ7T2Y1 | RZYQ8TY1 | RZYQ10TY1 | RZYQ7TA2Y1 | RZYQ8TAY1 | RZYQ10TAY1 | |
| Rated Capacity | Cool (kW) | 18.0 | 20.0 | 24.0 | 18.0 | 20.0 | 24.0 |
| Heat (kW) | 20.0 | 22.4 | 26.8 | 20.0 | 22.4 | 26.8 | |
| Capacity Range | Cool (kW) | 9.0-20.0 | 10.0-22.4 | 11.7-24.0 | 9.0-20.0 | 10.0-22.4 | 11.7-24.0 |
| Heat (kW) | 10.0-22.4 | 11.2-25.0 | 13.4-26.8 | 10.0-22.4 | 11.2-25.0 | 13.4-26.8 | |
| Power Input (Rated) | Cool (kW) | 5.61 | 6.08 | 7.47 | 5.60 | 6.08 | 7.47 |
| Heat (kW) | 5.81 | 6.17 | 8.14 | 5.81 | 6.17 | 8.14 | |
| E.E.R/C.O.P | C/H | 3.21/3.44 | 3.29/3.63 | 3.21/3.29 | 3.21/3.44 | 3.29/3.63 | 3.21/3.29 |
| TCSPF (Residential) | Hot/Average/Cold | 3.80/3.26/3.22 | 3.87/3.35/3.32 | 3.98/3.50/3.51 | 3.79/3.23/3.18 | 3.86/3.32/3.29 | 3.97/3.48/3.48 |
| HSPF (Residential) | Hot/Average/Cold | 3.21/3.15/3.02 | 3.42/3.35/3.20 | 3.60/3.37/3.15 | 3.21/3.15/3.02 | 3.42/3.35/3.20 | 3.60/3.37/3.15 |
| Airflow Rate (Nominal/Max) | l/s | 1160/1200 | 1200/1300 | 1400/1600 | 1160/1200 | 1200/1300 | 1400/1600 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 45.0/45.0 | 44.0/44.0 | 46.0/46.0 | 45.0/45.0 | 44.0/44.0 | 46.0/46.0 |
| Piping Length | m | 150 | 165 | ||||
| Indoor Fan Speeds | H/M/L | ||||||
| Dimensions (HxWxD) | Indoor (mm) | 470x1200x997 | 470x1400x997 | 470x1200x997 | 470x1400x997 | ||
| Outdoor (mm) | 1657x930x765 | ||||||
| Weight | Indoor (kg) | 70 | 79 | 85 | 70 | 79 | 85 |
| Outdoor (kg) | 192 | 192 | 203 | 185 | 185 | 200 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz | |||||
| Compressor Type | Hermetically Sealed Scroll Type | ||||||
| Refrigerant | R410A | ||||||
| Pipe Sizes | Liquid (mm) | 9.5 (Brazed) | |||||
| Gas (mm) | 19.1 (Brazed) | 22.2 (Brazed) | 19.1 (Brazed) | 22.2 (Brazed) | |||
| Drain (mm) | BSP 3/4 inch Internal Thread | BSP 3/4 inch Internal Thread | |||||
| Supply Air Opening | mm (HxW, Flange) | 350×918 | 350×1118 | 350×918 | 350×1118 | ||
| Return Air Opening | mm | 393×918 (Flange) | 393×1118 (Flange) | 393×918 (Flange) | 393×1118 (Flange) | ||
| Outdoor Operating Range | Cool (°CDB) | -5 to 49 | |||||
| Heat (°CWB) | -20 to 16 | ||||||
| EPA Sound Power Level | dBA | – | – | – | 76 | 76 | 78 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 56/56 | 56/56 | 57/57 | 56/56 | 56/56 | 57/57 |
All product information is provided as a guide only. Always check the manufacturer’s official site for updated specifications and details. https://www.daikin.com.au/products/residential/ducted-system-air-conditioning/premium-inverter-ducted
Brochures
Ducted Systems
A Daikin ducted system provides discreet air conditioned comfort throughout your entire home. It can be installed in a new home or tailored to suit an existing one, and once installed, only the controller, the return air and discharge grilles are visible inside your home.
Related Products
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
Fantech ProVent In-line Duct Mounted Fan Mixed Flow Inline with Plug & Lead Supply Exhaust Air Ceiling Floor Ventilation
Fantech EDM 150mm Wall Ceiling Mounted Exhaust Fan Backdraft Shutter Ventilation
Ø 10″ / 250mm x 6m Insulated Flexible Ducting – R0.6 Thermal & Fire Rated
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page
- Quick View
- Wishlist
- Select options This product has multiple variants. The options may be chosen on the product page