quotes@abaircon.com.au

810 Princes Highway, Tempe NSW 2044

Tel: (02) 9559 5116

Daikin ducted system – Standard Inverter

Daikin ducted system – Standard Inverter

Price range: $2,755.00 through $7,100.00

Engineered to deliver a compact and efficient design, the new Inverter series is ideal for installation into the tight roof space of any modern home.

Quantity
- +
Wishlist
SKU: N/A
Category:
  • Available in
    Reverse Cycle (Heating & Cooling)
  • Capacities
    5.0kW, 6.0kW, 7.1kW, 8.5kW, 10.0kW, 12.5kW, 14.0kW, 15.5kW, 18.0kW, 19.5kW, 20.0kW, 23.5kW
  • Refrigerant
    5.0-15.5kW: R32 / 18.0-23.5kW: R410A
Engineered to deliver a compact and efficient design, our Inverter series is ideal for installation into the tight roof space of any modern home and now also features R22 retrofit capability for 5.0-15.5kW models.
Note: Please check the manufacturer’s website for the most up to date information.
Weight 200 kg
Dimensions 120 × 120 × 120 cm
Sizes

5kw, 6kw, 7.1kw, 8.5kw, 10kw, 12.5kw, 14kw, 15.5kw, 18kw, 19.5kw, 23.5kw

Power

Single phase, Three phase

Tech Specs

Single Phase

Indoor Unit FDYAN50AV1 FDYAN60AV1 FDYAN71AV1 FDYAN85AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1
Outdoor Unit RZA50C2V1 RZA60C2V1 RZA71C2V1 RZA85C2V1 RZA100C2V1 RZA125C2V1 RZA140C2V1 RZA160C2V1
Rated Capacity Cool (kW) 5.0 6.0 7.1 8.5 10.0 12.5 14.0 15.5
  Heat (kW) 6.0 7.0 7.5 10.0 12.5 15.0 16.5 18.0
Capacity Range Cool (kW) 1.4-6.0 1.4-7.1 1.8-8.0 3.2-10.0 3.2-11.2 4.0-14.0 5.0-16.0 7.3-16.3
  Heat (kW) 1.4-7.1 1.4-8.0 2.0-9.0 3.5-11.2 3.5-14.0 4.1-16.0 5.1-18.0 7.3-18.2
Power Input (Rated) Cool (kW) 1.35 1.78 2.20 2.53 3.10 3.94 4.30 4.95
  Heat (kW) 1.62 1.95 1.93 2.80 3.35 4.00 4.50 4.90
E.E.R/C.O.P C/H 3.70/3.70 3.37/3.59 3.23/3.89 3.36/3.57 3.23/3.73 3.17/3.75 3.26/3.67 3.13/3.67
TCSPF (Residential) Hot/Average/Cold 4.42/3.72/3.65 4.35/3.75/3.75 4.42/3.86/3.92 4.28/3.84/3.89 4.28/3.87/3.96 4.25/3.90/4.01 4.19/3.86/3.96 4.05/3.76/3.86
HSPF (Residential) Hot/Average/Cold 4.51/4.02/3.49 4.46/3.76/3.15 4.17/3.85/3.41 3.97/3.67/3.32 3.85/3.48/3.04 4.31/3.31/2.77 3.90/3.51/3.05 3.87/3.53/3.12
Airflow Rate (Nominal/Max) l/s 315/370 340/400 425/566 580/600 680/800 755/840 900/1000 950/1120
Indoor Sound Level (H) @ 1.5m dBA (C/H) 33.3/35.0 34.1/35.9 37.3/40.5 42.0/42.4 43.5/45.8 44.2/45.5 46.6/47.9 47.9/50.7
Piping Length m 50
Indoor Fan Speeds   H/M/L
Dimensions (HxWxD) Indoor (mm) 300x1210x900 360x1520x935
  Outdoor (mm) 595x845x300 990x940x320 1430x940x320
Weight Indoor (kg) 37 37 40 40 45 55 55 56
  Outdoor (kg) 45 45 45 69 69 78 93 99
Power Supply V/Hz 1 Phase, 220-240V, 50Hz
Compressor Type   Hermetically Sealed Swing Type
Refrigerant   R32
Pipe Sizes Liquid (mm) 6.4 (Flare) 9.5 (Flare)
  Gas (mm) 12.7 (Flare) 15.9 (Flare)
  Drain (mm) ID 25 / OD 32
Supply Air Opening mm (HxW, Flange) 185×852 245×1152
Return Air Opening mm 1×400 (Oval) 2×350 (Oval) 2×400 (Oval)
Outdoor Operating Range Cool (°CDB) -5 to 46
  Heat (°CWB) -15 to 16
EPA Sound Power Level dBA 68 68 68 70 71 72 73 75
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 48/51 48/51 48/51 51/54 52/54 53/56 54/56 56/58

Three Phase

Indoor Unit FDYAN71AV1 FDYAN85AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1 FDYQN180LCV1 FDYQN200LCV1 FDYQN250LBV1
Outdoor Unit RZA71C2Y1 RZA85C2Y1 RZA100C2Y1 RZA125C2Y1 RZA140C2Y1 RZA160C2Y1 RZQ180M2Y1 RZQ200MY1 RZQ250LY1
Rated Capacity Cool (kW) 7.1 8.5 10.0 12.5 14.0 15.5 18.0 19.5 23.5
  Heat (kW) 7.5 10.0 12.5 15.0 16.5 18.0 20.0 22.4 26.8
Capacity Range Cool (kW) 3.2-8.0 3.2-10.0 3.2-11.2 4.0-14.0 5.0-16.0 7.3-16.3 9.0-18.0 10.1-19.5 15.0-23.5
  Heat (kW) 3.5-9.0 3.5-11.2 3.5-14.0 4.1-16.0 5.1-18.0 7.3-18.2 10.0-20.0 11.2-22.4 16.8-26.8
Power Input (Rated) Cool (kW) 2.20 2.53 3.10 3.94 4.30 4.95 5.82 6.11 7.85
  Heat (kW) 1.93 2.80 3.35 4.00 4.50 4.90 6.11 6.85 8.47
E.E.R/C.O.P C/H 3.23/3.89 3.36/3.57 3.23/3.73 3.17/3.75 3.26/3.67 3.13/3.67 3.09/3.27 3.19/3.27 2.99/3.16
TCSPF (Residential) Hot/Average/Cold 4.44/3.91/3.98 4.28/3.84/3.89 4.28/3.87/3.96 4.25/3.90/4.01 4.19/3.86/3.96 4.05/3.76/3.86 3.61/3.15/3.12 3.57/3.14/3.11 3.73/3.41/3.46
HSPF (Residential) Hot/Average/Cold 4.17/3.90/3.55 3.97/3.67/3.32 3.85/3.48/3.04 4.31/3.31/2.77 3.90/3.51/3.05 3.87/3.53/3.12 3.23/2.95/2.61 3.25/2.97/2.63 3.41/3.08/2.72
Airflow Rate (Nominal/Max) l/s 425/566 580/600 680/800 755/840 900/1000 950/1120 1160/1200 1400/1600 1400/1600
Indoor Sound Level (H) @ 1.5m dBA (C/H) 37.3/40.5 42.0/42.4 43.5/45.8 44.2/45.5 46.6/47.9 47.9/50.7 45.0/45.0 46.0/46.0 49.5/49.5
Piping Length m 50
Indoor Fan Speeds   H/M/L
Dimensions (HxWxD) Indoor (mm) 300x1210x900 360x1520x935 470x1200x997 470x1400x997 500x1430x970
  Outdoor (mm) 990x940x320 1430x940x320 1680x930x765
Weight Indoor (kg) 40 40 45 55 55 56 70 85 92
  Outdoor (kg) 69 69 69 78 93 99 138 138 193
Power Supply V/Hz 3 Phase, 380-415V, 50Hz
Compressor Type   Hermetically Sealed Swing Type Hermetically Sealed Scroll Type
Refrigerant   R32 R410A
Pipe Sizes Liquid (mm) 9.5 (Flare) 9.5 (Brazed)
  Gas (mm) 15.9 (Flare) 19.1 (Brazed) 22.2 (Brazed)
  Drain (mm) ID 25/OD 32 BSP 3/4 inch Internal Thread
Supply Air Opening mm (HxW, Flange) 185×852 245×1152 350×918 350×1118 376×938
Return Air Opening mm 1×400 (Oval) 2×350 (Oval) 2×400 (Oval) 393×918 (Flange) 393×1118 (Flange) 350×1118 (Flange)
Outdoor Operating Range Cool (°CDB) -5 to 46 -5 to 43
  Heat (°CWB) -15 to 16 -20 to 16
EPA Sound Power Level dBA 67 70 71 72 73 75 72 74 79
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 48/50 51/54 52/54 53/56 54/56 56/58 57/58 58/59 57/58

All product information is provided as a guide only. Always check the manufacturer’s official site for updated specifications and details. https://www.daikin.com.au/products/residential/ducted-system-air-conditioning/inverter-ducted

Brochures

Ducted Systems
A Daikin ducted system provides discreet air conditioned comfort throughout your entire home. It can be installed in a new home or tailored to suit an existing one, and once installed, only the controller, the return air and discharge grilles are visible inside your home.

Download Brochure

0

Your Cart Is Empty

No products in the cart.

Scroll to Top