$0.00$3,570.00

The FDU series of ducted air conditioning systems are a quiet and discreet climate solution for your entire home. Ranging from 7.1kW up to 14kW, the FDU series incorporates a compact design, a range of convenient features and functions including high power mode, silent mode and several timer and scheduling functions.

Quantity
Wishlist
SKU: N/A
Category:

POWER: Single Phase & Three Phase  | AVAILABLE IN: Reverse Cycle

CAPACITIES: 7.1kW | 10.0kW | 12.1kW |12.5kW | 14.0kW

Key features

  • Slimline design
  • High Power Mode for rapid cooling and heating
  • Weekly & Sleep timers
  • Silent operation
  • Dry operation to reduce humidity
Weight 200 kg
Dimensions 120 × 120 × 120 cm
Sizes

7.1kw, 10kw, 10kw, 12.1kw, 12.5kw, 14kw

Power

Single phase, Three phase

Technical Specifications

A B C D E F G H I J K L M N O
Set FDU71AVNXWVH FDU100AVNAWVH FDU100AVNPWVH FDU125VNPWVH FDU125AVNPWVH FDU125AVNXWVH FDU140AVNXWVH FDU100AVSAWVH FDU125AVSXWVH FDU140AVSXWVH
Indoor FDU71VH FDU100VH FDU100VH FDU125VH FDU125VH FDU125VH FDU140VH FDU100VH FDU125VH FDU140VH
Outdoor FDCA71VNX-W FDCA100VNA-W FDCA100VNP-W FDC125VNP-W FDCA125VNP-W FDCA125VNX-W FDCA140VNX-W FDCA100VSA-W FDCA125VSX-W FDCA140VSX-W
Power source (Outdoor Unit) 1 Phase 240V 50Hz 3 Phase 380-415V 50Hz
*Operation
data
Nominal Capacity (Range) Cooling T1 kW 7.1 (3.2-8.0) 10.0 (4.0-11.2) 10 (2.1 -10.2) 12.1 (5.0-12.1) 12.1 (5.0-12.1) 12.5 (3.5-14.0) 14.0 (3.5-16.0) 10.0 (4.0-11.2) 12.5 (3.5-14.0) 14.0 (3.5-16.0)
Heating H1 8.0 (3.6-9.0) 11.2 (4.0-12.5) 10 (1.7 – 10.4) 12.1 (4.0-13.3) 12.1 (4.0-13.3) 14.0 (2.7-17.0) 16.0 (2.7-18.0) 11.2 (4.0-12.5) 14.0 (2.7-18.0) 16.0 (2.7-20.0)
Heating H2 7.4 10 7.6 7.9 7.9 13.1 15.5 10 13.1 15.5
Power consumption Cooling T1 kW 1.77 2.99 3.08 3.85 3.85 3.49 4.22 2.99 3.49 4.22
Heating H1 1.78 2.66 2.45 3.28 3.28 3.61 4.22 2.66 3.61 4.22
Maximum power consumption kW 4.11 6.4 4.46 4.75 4.75 7.1 7.1 10.2 8.9 8.9
Running current Cooling T1 A 7.9 14.3 13.1 16.2 16.2 15.3 18.5 4.6 5.6 6.7
Heating H1 7.9 12.7 10.4 13.8 13.8 15.9 18.5 4.1 5.9 6.8
Inrush current, maximum current A 5, 20 5, 26 5, 19 5, 20 5, 20 5, 28 5, 30 5, 17 5, 16 5, 17
EER Cooling T1 4.01 3.35 3.25 3.14 3.14 3.58 3.32 3.35 3.58 3.32
COP Heating H1 4.49 4.21 4.08 3.69 3.69 3.88 3.79 4.21 3.88 3.79
Sound power level
(JIS C9612)
Outdoor dB(A) 66 70 68 73 73 68 69 69 68 69
Sound pressure level
(JIS C9612)
Indoor dB (A) P-Hi:38 Hi:33
Me:29 Lo:25
P-Hi:44 Hi:38
Me:36 Lo:30
P-Hi: 44 Hi: 38
Me: 36 Lo: 30
P-Hi:45 Hi:40
Me:34 Lo:29
P-Hi:45 Hi:40
Me:34 Lo:29
P-Hi:45 Hi:40
Me:34 Lo:29
P-Hi:47 Hi:40
Me:35 Lo:30
P-Hi:44 Hi:38
Me:36 Lo:30
P-Hi:45 Hi:40
Me:34 Lo:29
P-Hi:47 Hi:40
Me:35 Lo:30
Outdoor 51 55 56 57 57 54 54 55 54 54
External dimensions (HxWxD) Indoor mm 280x950x635 280×1370×740 280x1370x740 280×1370×740 280×1370×740 280×1370×740 280×1370×740 280×1370×740 280×1370×740 280×1370×740
Outdoor 750×880(+88)x340 845x970x370 750 × 880(+88) × 340 845x970x370 845x970x370 1300x970x370 1300x970x370 845x970x370 1300x970x370 1300x970x370
Net weight Indoor kg 34 54 54 54 54 54 54 54 54 54
Outdoor 60 77 57 73 73 97 97 78 99 99
Supply air connection mm 170×880 170×1200 170×1200 170×1200 170×1200 170×1200 170×1200 170×1200 170×1200 170×1200
Return air connection mm 200×740 235×1280 235×1280 235×1280 235×1280 235×1280 235×1280 235×1280 235×1280 235×1280
External Static Pressure (max) Pa 200 200 200 200 200 200 200 200 200 200
Airflow Indoor (Cooling) l/s P-Hi: 400 Hi: 316
Me: 250 Lo: 166
P-Hi: 600 Hi: 467
Me: 417 Lo: 317
P-Hi:600 Hi:467 Me:417 Lo:317 P-Hi:650 Hi:533 Me:433 Lo:333 P-Hi:650 Hi:533 Me:433 Lo:333 P-Hi:650 Hi:533 Me:433 Lo:333 P-Hi:800 Hi:583 Me:467 Lo:367 P-Hi: 600 Hi: 467
Me: 417 Lo: 317
P-Hi:650 Hi:533 Me:433 Lo:333 P-Hi:800 Hi:583 Me:467 Lo:367
Indoor (Heating)
Refrigerant (R32) Quantity kg 2.75 3.3 1.7 2.25 2.25 4 4 3.3 4 4
Pre charged to pipe length m 30 30 15 15 15 30 30 30 30 30
Installation data Refrigerant piping Liquid line mm Ø9.52 Ø9.52 Ø6.35** Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52
Gas line Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88
Connection method Flare Connection Flare Connection
Maximum pipe (one way) length m 50 50 30 30 30 100 100 50 100 100
Max vertical height diff. between O.U. and I.U. m 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Motion Sensor (Optional) LB-KIT2 LB-KIT2
Demand response (AS4755) Yes Yes Yes No Yes Yes Yes Yes Yes Yes
Outdoor air temperature (upper, lower limits) Cooling C -15 to 50 -15 to 50 -15 to 46 -15 to 46 -15 to 46 -15 to 50 -15 to 50 -15 to 50 -15 to 50 -15 to 50
Heating C -20 to 20 -20 to 20 -15 to 20 -15 to 20 -15 to 20 -20 to 20 -20 to 20 -20 to 20 -20 to 20 -20 to 20
* Operation data has been gathered in accordance with AS/NZS 3823 standards.