POWER: Single Phase | AVAILABLE IN: Reverse Cycle
CAPACITIES: 5.0kW | 5.6kW
Key features
- Silent operation
- High power mode for rapid cooling and heating
- Weekly / Sleep timers
- Dry operation to reduce humidity
- Economy mode
$0.00
The FDUM series of ducted systems are a quiet and compact solution for heating and cooling multiple rooms. Coming in 5.0kW and 5.6kW capacities, the FDUM series incorporates a range of convenient features and functions including Automatic Mode, High Power Mode, Silent Mode and a range of timer and scheduling functions making them the perfect climate solution for smaller Aussie homes.
POWER: Single Phase | AVAILABLE IN: Reverse Cycle
CAPACITIES: 5.0kW | 5.6kW
Sizes | 5.0, 5.6 |
---|
A | B | C | D | E | F | G | |
---|---|---|---|---|---|---|---|
Set | FDUM50ZSXAWVH | FDUM60ZSXAWVH | |||||
Indoor | FDUM50VH | FDUM60VH | |||||
Outdoor | SRC50ZSXA-W | SRC60ZSXA-W | |||||
Power source (Outdoor Unit) | 1 Phase 240V 50Hz | ||||||
*Operation data |
Nominal Capacity (Range) | Cooling T1 | kW | 5.0 (1.1-5.6) | 5.6 (1.1-6.3) | ||
Heating H1 | 5.4 (0.6-6.3) | 6.7 (0.6-7.1) | |||||
Heating H2 | 4.8 | 4.8 | |||||
Power consumption | Cooling T1 | kW | 1.51 | 1.53 | |||
Heating H1 | 1.59 | 1.75 | |||||
Maximum power consumption | kW | 2.9 | 2.9 | ||||
Running current | Cooling T1 | A | 6.9 | 6.8 | |||
Heating H1 | 7.2 | 7.8 | |||||
Inrush current, maximum current | A | 5, 15 | 5, 15 | ||||
EER | Cooling T1 | 3.31 | 3.64 | ||||
COP | Heating H1 | 3.39 | 3.83 | ||||
Sound power level (JIS C9612) | Outdoor | dB(A) | 63 | 65 | |||
Sound pressure level (JIS C9612) | Indoor | dB (A) | P-Hi:37 Hi:32 Me:29 Lo:26 |
P-Hi:36 Hi:31 Me:28 Lo:25 |
|||
Outdoor | 52 | 54 | |||||
External dimensions (HxWxD) | Indoor | mm | 280x750x635 | 280x950x635 | |||
Outdoor | 640×800(+71)x290 | 640×800(+71)x290 | |||||
Net weight | Indoor | kg | 29 | 34 | |||
Outdoor | 45 | 45 | |||||
Supply air connection | mm | 170×680 | 170×880 | ||||
Return air connection | mm | 200×660 | 200×860 | ||||
External Static Pressure (max) | Pa | 100 | 100 | ||||
Airflow | Indoor (Cooling) | l/s | P-Hi: 217 Hi: 167 Me: 150 Lo: 133 | P-Hi:333 Hi:250 Me:217 Lo:167 | |||
Indoor (Heating) | |||||||
Refrigerant (R32) | Quantity | kg | 1.3 | 1.3 | |||
Pre charged to pipe length | m | 15 | 15 | ||||
Installation data | Refrigerant piping | Liquid line | mm | Ø6.35 | Ø6.35 | ||
Gas line | Ø12.7 | Ø12.7 | |||||
Connection method | Flare Connection | ||||||
Maximum pipe (one way) length | m | 30 | 30 | ||||
Max vertical height diff. between O.U. and I.U. | m | 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) | |||||
Controller | RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 | ||||||
Motion Sensor (Optional) | LB-KIT2 | ||||||
Demand response (AS4755) | Yes | ||||||
Outdoor air temperature (upper, lower limits) | Cooling | C | -15 to +46 | -15 to +46 | |||
Heating | C | -20 to +20 | -20 to +20 |