| 1 phase |
Set |
FDUA100AVNPWVH |
FDUA100AVNAWVH |
FDUA125VNPWVH |
FDUA125AVNPWVH |
FDUA125AVNXWVH |
FDUA140AVNXWVH |
FDUA160AVNXWVH |
3 phase |
Set |
FDUA100AVSAWVH |
FDUA125AVSXWVH |
FDUA140AVSXWVH |
FDUA160AVSAWVH |
FDUA200AVSAWVH |
FDUA250AVSAWVH |
| Indoor |
FDUA100VH |
FDUA100VH |
FDUA125VH |
FDUA125VH |
FDUA125VH |
FDUA140VH |
FDUA160VH |
Indoor |
FDUA100VH |
FDUA125VH |
FDUA140VH |
FDUA160VH |
FDUA200VH |
FDUA250VH |
| Outdoor |
FDCA100VNP-W |
FDCA100VNA-W |
FDC125VNP-W |
FDCA125VNP-W |
FDCA125VNX-W |
FDCA140VNX-W |
FDCA160VNX-W |
Outdoor |
FDCA100VSA-W |
FDCA125VSX-W |
FDCA140VSX-W |
FDCA160VSA-W |
FDCA200VSA-W |
FDCA250VSA-W |
| Power source (Outdoor Unit) |
|
1 Phase 240V 50Hz |
|
Power source (Outdoor Unit) |
|
3 Phase 380-415V 50Hz |
| *Operation data |
Nominal Capacity (Range) |
Cooling T1 |
kW |
10 (2.1 -10.2) |
10.0 (4.0-11.2) |
12.1 (5.0-12.1) |
12.1 (5.0-12.1) |
12.5 (5.0-14.0) |
14.0 (5.0-14.5) |
16.0 (5.0-17.0) |
*Operation data |
Nominal Capacity (Range) |
Cooling T1 |
kW |
10.0 (4.0-11.2) |
12.5 (5.0-14.0) |
14.0 (5.0-14.5) |
16.0 (6.9-20.0) |
20.0 (6.9-28.0) |
23.5 [ 6.9(Min.) – 28.0(Max.)] |
| Heating H1 |
10 (1.7 – 10.4) |
11.2 (4.0-12.5) |
12.1 (4.0-13.3) |
12.1 (4.0-13.3) |
14.0 (4.0-17.0) |
16.0 (4.0-18.0) |
18.0 (4.0-21.0) |
Heating H1 |
11.2 (4.0-12.5) |
14.0 (4.0-18.0) |
16.0 (4.0-18.0) |
18.0 (5.5-22.4) |
22.4(5.5-31.5) |
28.0 [ 5.5(Min.) – 31.5(Max.)] |
| Heating H2 |
7.6 |
10 |
7.9 |
7.9 |
14.2 |
15.5 |
15 |
Heating H2 |
10 |
14.2 |
15.5 |
16.1 |
21 |
21.1 |
| Power consumption |
Cooling T1 |
kW |
2.99 |
3.05 |
3.85 |
3.85 |
3.83 |
4.02 |
5 |
Power consumption |
Cooling T1 |
kW |
3.05 |
3.83 |
4.02 |
4.68 |
5.78 |
7.7 |
| Heating H1 |
2.57 |
2.87 |
3.28 |
3.28 |
3.68 |
4.19 |
5 |
Heating H1 |
2.87 |
3.68 |
4.19 |
4.6 |
5.44 |
7.7 |
| Maximum power consumption |
kW |
4.46 |
6.4 |
4.75 |
4.75 |
6.13 |
5.77 |
7.1 |
Maximum power consumption |
kW |
10.2 |
7.66 |
7.26 |
11.2 |
11.2 |
11.2 |
| Running current |
Cooling T1 |
A |
13.2 |
14.7 |
16.2 |
16.2 |
17 |
17.8 |
22 |
Running current |
Cooling T1 |
A |
4.7 |
6.4 |
6.7 |
7.5 |
9.1 |
12 |
| Heating H1 |
11.4 |
14 |
13.8 |
13.8 |
16.3 |
18.6 |
22 |
Heating H1 |
4.4 |
6.2 |
6.9 |
7.5 |
8.6 |
12 |
| Inrush current, maximum current |
|
A |
5, 19 |
5, 26 |
5, 20 |
5, 20 |
5, 29 |
5, 30 |
5, 30 |
Inrush current, maximum current |
A |
5, 17 |
5, 18 |
5, 19 |
5, 24 |
5, 27 |
5, 27 |
| EER |
Cooling T1 |
|
3.34 |
3.28 |
3.14 |
3.14 |
3.26 |
3.48 |
3.16 |
EER |
Cooling T1 |
|
3.28 |
3.26 |
3.48 |
3.42 |
3.46 |
3.16 |
| COP |
Heating H1 |
3.89 |
3.9 |
3.69 |
3.69 |
3.8 |
3.82 |
3.6 |
COP |
Heating H1 |
3.9 |
3.8 |
3.82 |
3.91 |
4.12 |
3.67 |
| Sound power level (JIS C9612) |
Outdoor |
dB(A) |
68 |
69 |
73 |
73 |
68 |
69 |
69 |
Sound power level (JIS C9612) |
Outdoor |
dB(A) |
69 |
68 |
69 |
73 |
73 |
73 |
| Sound pressure level (JIS C9612) |
Indoor |
dB (A) |
P-Hi:43 Hi:42 Me:40 Lo:37 |
P-Hi:43 Hi:42 Me:40 Lo:37 |
P-Hi:46 Hi:44 Me:42 Lo:38 |
P-Hi:46 Hi:44 Me:42 Lo:38 |
P-Hi:46 Hi:44 Me:42 Lo:38 |
P-Hi:48 Hi:47 Me:43 Lo:38 |
P-Hi : 48 Hi : 47 Me : 43 Lo : 41 |
Sound pressure level (JIS C9612) |
Indoor |
dB (A) |
P-Hi:43 Hi:42 Me:40 Lo:37 |
P-Hi:46 Hi:44 Me:42 Lo:38 |
P-Hi:48 Hi:47 Me:43 Lo:38 |
P-Hi:48 Hi:47 Me:43 Lo:41 |
P-Hi:52 Hi:50 Me:47 Lo:45 |
P-Hi : 52 Hi : 50 Me : 47 Lo : 45 |
| Outdoor |
56 |
55 |
57 |
57 |
54 |
54 |
54 |
Outdoor |
55 |
54 |
54 |
58 |
58 |
58 |
| External dimensions (HxWxD) |
Indoor |
mm |
398×1150(+86)x650 |
398×1150(+86)x650 |
398×1150(+86)x650 |
398×1150(+86)x650 |
398×1150(+86)x650 |
398x1450x930 |
398 × 1450 × 930 |
External dimensions (HxWxD) |
Indoor |
mm |
398×1150(+86)x650 |
398×1150(+86)x650 |
398x1450x930 |
398x1450x930 |
379×1600(+85)x893 |
379×1600(+85)x893 |
| Outdoor |
750 × 880(+88) × 340 |
845x970x370 |
845x970x370 |
845x970x370 |
1300x970x370 |
1300x970x370 |
1300 × 970 × 370 |
Outdoor |
845x970x370 |
1300x970x370 |
1300x970x370 |
1505x970x370 |
1505x970x370 |
1505x970x370 |
| Net weight |
Indoor |
kg |
52 |
52 |
52 |
52 |
52 |
66 |
66 |
Net weight |
Indoor |
kg |
54 |
52 |
66 |
66 |
88 |
88 |
| Outdoor |
57 |
77 |
73 |
73 |
97 |
97 |
97 |
Outdoor |
78 |
99 |
99 |
145 |
145 |
145 |
| Supply air connection |
mm |
348×898 |
348×898 |
348×898 |
348×898 |
348×898 |
298×1064 |
298×1064 |
Supply air connection |
mm |
348×898 |
348×898 |
298×1064 |
298×1064 |
250×1450 |
250×1450 |
| Return air connection |
mm |
348×898 |
348×898 |
348×898 |
348×898 |
348×898 |
2 X φ400 |
2 X φ400 |
Return air connection |
mm |
348×898 |
348×898 |
2 X φ400 |
2 X φ400 |
250×1450 |
250×1450 |
| External Static Pressure (max) |
Pa |
200 |
200 |
200 |
200 |
200 |
150 |
150 |
External Static Pressure (max) |
Pa |
200 |
200 |
150 |
150 |
200 |
200 |
| Airflow |
Indoor (Cooling) |
l/s |
P-Hi:650 Hi:600 Me:550 Lo:483 |
P-Hi:650 Hi:600 Me:550 Lo:483 |
P-Hi:717 Hi:650 Me:600 Lo:500 |
P-Hi:717 Hi:650 Me:600 Lo:500 |
P-Hi:717 Hi:650 Me:600 Lo:500 |
P-Hi:1000 Hi:867 Me:733 Lo:600 |
P-Hi : 1000 Hi : 867 Me : 733 Lo : 683 |
Airflow |
Indoor (Cooling) |
l/s |
P-Hi:650 Hi:600 Me:550 Lo:483 |
P-Hi:717 Hi:650 Me:600 Lo:500 |
P-Hi:1000 Hi:867 Me:733 Lo:600 |
P-Hi:1000 Hi:866 Me:733 Lo:683
|
P-Hi:1333 Hi:1200 Me:1067 Lo:933 |
P-Hi:1333 Hi:1200 Me:1067 Lo:933 |
| Indoor (Heating) |
P-Hi : 1000 Hi : 867 Me : 733 Lo : 600 |
Indoor (Heating) |
P-Hi:1000 Hi:866 Me:733 Lo:600
|
| Refrigerant (R32) |
Quantity |
kg |
1.7 |
3.3 |
2.25 |
2.25 |
4 |
4 |
4 |
Refrigerant (R32) |
Quantity |
kg |
3.3 |
4 |
4 |
5.1 |
5.1 |
5.1 |
|
Pre charged to pipe length
|
m |
15 |
30 |
15 |
15 |
30 |
30 |
30 |
Pre charged to pipe length
|
m |
30 |
30 |
30 |
30 |
30 |
30 |
| Installation data |
Refrigerant piping |
Liquid line |
mm |
**Ø6.35 |
**Ø6.35 |
Ø9.52 |
Ø9.52 |
Ø9.52 |
Ø9.52 |
Ø9.52 |
Installation data |
Refrigerant piping |
Liquid line |
mm |
Ø9.52 |
Ø9.52 |
Ø9.52 |
Ø12.7 |
Ø12.7 |
Ø12.7 |
| Gas line |
Ø15.88 |
Ø15.88 |
Ø15.88 |
Ø15.88 |
Ø15.88 |
Ø15.88 |
Ø15.88 |
Gas line |
Ø15.88 |
Ø15.88 |
Ø15.88 |
Ø22.22 , Ø25.4 or Ø28.58 |
Ø22.22 , Ø25.4 or Ø28.58 |
Ø22.22 , Ø25.4 or Ø28.58 |
| Connection method |
|
Flare Connection |
Connection method |
|
Flare Connection |
Liquid : Flare / Gas : Brazing |
| Maximum pipe (one way) length |
m |
30 |
50 |
30 |
30 |
100 |
100 |
100 |
Maximum pipe (one way) length |
m |
50 |
100 |
100 |
**70 |
**70 |
**70 |
| Max vertical height diff. between O.U. and I.U. |
m |
20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
|
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
|
20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) |
30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) |
***50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
|
Max vertical height diff. between O.U. and I.U. |
m |
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
|
30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) |
***50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
|
| Controller |
RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 |
Controller |
RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 |
| Safety Pan (Optional) |
UA-SP2-E (Optional) |
UA-SP2-E (Optional) |
UA-SP2-E (Optional) |
UA-SP2-E (Optional) |
UA-SP2-E (Optional) |
NA |
NA |
Safety pan (Optional) |
UA-SP2-E (Optional) |
NA |
NA |
NA |
NA |
| Motion Sensor (Optional) |
LB-KIT2 |
Motion Sensor (Optional) |
LB-KIT2 |
| Demand response (AS4755) |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
Demand response (AS4755) |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Outdoor air temperature (upper, lower limits) |
Cooling |
C |
-15 to 46 |
-15 to 50 |
-15 to 46 |
-15 to 46 |
-15 to 50 |
-15 to 50 |
-15 to 50 |
Outdoor air temperature (upper, lower limits) |
Cooling |
C |
-15 to 50 |
-15 to 50 |
-15 to 50 |
-15 to 50 |
-15 to 50 |
-15 to 50 |
|
Heating |
C |
-15 to 20 |
-20 to 20 |
-15 to 20 |
-15 to 20 |
-20 to 20 |
-20 to 20 |
-20 to 20 |
Heating |
C |
-20 to 20 |
-20 to 20 |
-20 to 20 |
-20 to 20 |
-20 to 20 |
-20 to 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* Operation data are are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Page xxx |
|
|
|
|
|
|
|
* Operation data are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Pagexxx |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
**Reducer set Ø9.52 –> Ø6.35 is included in the outdoor unit as accessory for FDCA100VNP-W. |
|
|
|
|
|
|
|
** Maximum 70m(Gas piping:φ25.4 or φ28.58), Maximum 35m(Gas piping:φ22.22) |
|
|
|
|
|