Price range: $1,470.00 through $2,090.00

Powerful yet quiet, the Wera® series of floor standing systems is perfect for rooms where wall space is limited.

With the ability to select air outlet, high performance in low temps and high power mode to deliver rapid heating and cooling, the Wera® series is perfect solution for keeping small and medium spaces comfortable all year round.

Quantity
Wishlist
SKU: N/A
Category:

POWER: Single Phase  | AVAILABLE IN: Reverse Cycle

CAPACITIES: 2.5kW | 3.5kW | 5.0kW

Key features

  • Air Outlet selection for complete airflow control
  • Allergen Clear Filter to capture and neutralise airborne allergens
  • High Power mode for rapid heating and cooling
  • Optional Wi-Fi control

Brochure

Weight 150 kg
Dimensions 120 × 120 × 120 cm
Sizes

2.5kw, 3.5kw, 5kw

Technical Specifications

A B C D E F G H
Indoor SRF25ZS-W SRF35ZS-W SRF50ZSX-W
Outdoor SRC25ZSA-W SRC35ZSA-W SRC50ZSXA-W
Power source (Outdoor Unit) 1 Phase 240V 50Hz
*Operation
data
Nominal Capacity (Range) Cooling T1 kW 2.5 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (1.1~5.6)
Heating H1 3.4 (0.9~4.7) 4.5 (0.8~5.2) 6.0 (0.8~7.4)
Heating H2 3.45 3.8 5.6
Power consumption Cooling T1 kW 0.50 (0.17~0.82) 0.82 (0.18~1.33) 1.32 (0.19~1.90)
Heating H1 0.74 (0.19~1.29) 1.12 (0.19~1.53) 1.58 (0.19~2.34)
Maximum power consumption kW 1.65 1.65 2.9
Running current Cooling T1 A 2.5 3.7 5.6
Heating H1 3.4 4.9 6.6
Inrush current, maximum current A 3.6, 9.0 5.0, 9,0 5.0, 15.0
EER Cooling T1 5 4.27 3.79
COP Heating H1 4.59 4.02 3.8
Sound power level
(JIS C9612)
Outdoor dB(A) 60 63 63
Sound pressure level
(JIS C9612)
Indoor dB(A) 37-32-29-26 40-35-33-29 46-38-33-28
Outdoor 46 50 51
Energy label (GEMS 2019) HOT Cooling 4 4 3.5
Heating 3.5 3 3
AVERAGE Cooling 3.5 3.5 3
Heating 3 2.5 2.5
COLD Cooling 3.5 3.5 3
Heating 2.5 2 2
External dimensions (HxWxD) Indoor mm 600x860x238 600x860x238 600x860x238
Outdoor 540×780(+62)x290 540×780(+62)x290 640×800(+71)x290
Net weight Indoor kg 18 19 19
Outdoor 34.5 34.5 45
Airflow Indoor (Cooling) l/s 150-126-111-96 153-130-121-106 192-160-123-110
Indoor (Heating) 175-136-128-110 178-138-135-123 200-167-157-127
Refrigerant (Type, amount, pre-charge length) Quantity kg (R32) 0.78 (R32) 0.78 (R32) 1.30
Pre charged to pipe length m 15 15 15
Installation data Refrigerant piping Liquid line mm Ø6.35 Ø6.35 Ø6.35
Gas line Ø9.52 Ø9.52 Ø12.7
Connection method Flare connection
Maximum pipe (one way) length m 20 30
Max vertical height diff. between O.U. and I.U. m 10 ( O.U. above I.U. ) / 10 ( O.U. below I.U. ) 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
Standard accessories Allergen clear filter & Photocatalytic Washable Deodorizing Filter
Optional parts Interface kit (SC-BIKN2-E) / Wi-Fi Kit
Demand response (AS4755) Yes